gbXML version 0.36 - maintained by Green Building Studio, Inc.
Change Log:
0.36
02/08
Corrected buildingStoreyIdRef attribute in Space element.
Added HydronicLoopEquipmentId element to Space element.
Added airChangesSchedIdRef attribute to Zone element.
Add constraint to Surface element to have a minimum of four defined.
Corrected spelling error in PercentAreaDaylitControlled element in LightingControl element.
Added the following elements to allow USDA-FS to conduct urban/wildland interface fire modeling: BiomassDensity element to Vegetation element, WFTDTemp, WFTDRelHumidity, WFTDWindSpeed, WFTDWindDir, and WFTDPressure to Weather element, Fire to Material element and FireFace to Construction element.
Changed DocumentHistory/CreatedBy and DocumentHistory/ProgramInfo elements to be required.
0.35
8/06
Corrected spelling error in capacityTypeEnum.
Added SingleFamily to buildingTypeEnum.
Replaced sequence requirement with unbound choice.
0.34
8/19/03
Convert spaceTypeEnum facets to Pascal case and added DiningCafeteriaFastFood to buildingTypeEnum. Ensured all enumeration facets are in Pascal case.
6/25/03
Added CartesianPoint element to Results element.
Set minNumber for ZipcodeOrPostalCode element under the Location element to 1.
Set Campus element id attribute use to required.
Set Building element id attribute use to required.
Corrected Surface element id attribute use to required.
0.33
1/15/02
Added PolyLoop element to RectangularGeometry for describing polygons
Changed CartesianPoint element to allow only two Coordinate elements for describing flat geometry
Added PeakDomesticHotWaterFlow element to Building
Created PeakDomesticHotWaterFlow element
Moved simple type elements into complex type elements - easier to find correct element
Added enumeration to conditionTypeEnum
1/14/02
Made HydronicLoopId repeatable in AirLoopEquipment and HydronicLoopEquipment
Added Name and Description as optional elements to the Results element
1/10/02
Created heatGainTypeEnum enumeration and assigned it to the PeopleHeatGain element
Created PeopleHeatGain element and added it to the Space element
Removed TotalPeopleHeatGain and PeopleLatentHeatGain elements
Added systemType attribute to the AirLoop element, and added systemTypeEnum enumeration
Removed Lighting element from gbXML root element
Replaced LightId in Campus and Building elements with Lighting elements that refrence LightingSystem elements directly
Changed InfiltrationFlow/@type to optional
Added an optional HydronicLoop/@primaryLoopId attribute
0.32
12/12/01
Changed xsd:any namespace="##any" to ##other for GeneralGeometry and Meter elements
12/10/01
Removed gbXML/CreatorPersonInfo and gbXML/CreatorCadInfo
Created Surface/RectangularGeometry and Opening/RectangularGeometry and their children
Created gbXML/DocumentHistory and its children
Updated schema to version http://www.w3.org/2001/XMLSchema
Changed enumerations for spaceTypeEnum to remove spaces and slashes
Changed Results/@timeIncrement to type xsd:duration as required for the 2001 schema specification
0.31
8/1/01
Added HydronicLoopId to AirLoopEquipment element
7/26/01
Added Control element to equipment elements
Added FlowControl element to HydronicLoop element
Added PressureControl element to AirLoop element
Added TemperatureControl element to both loop elements
Added enumerations to tempTypeEnum
7/25/01
Added xmlns to schema element
Added conditioningTypeEnum
Changed enumerations for efficiencyTypeEnum
Changed enumerations for resourceTypeEnum
Added stadardsTypeEnum
Added DependantValue element
Added IndependantValue element
Removed XValue element
Removed YValue element
Added RefrigerantType to AirLoopEquipment element
Changed structure of Data element
Added attributes to DeltaP element
Added conditionType attribute to DeltaT element
Made Name and Description elements optional in the DependantVariable element
Added minValue and maxValue attributes to the DependantVariable element
Changed structure of the Efficiency element
Allowed up to 2 IndependantVariable elements in the Equation element
Added fluidType attribute to the HydronicLoop element
Changed structure of HydronicLoopEquipment element
Made Name in IndependantVariable element optional
Changed structure of MinFlow element
Added id attribute to the Performance element
Changed structure of PointData element
7/9/01
Added hydronicLoopType to HydronicLoopId
Added HydronicLoopId to HydronicLoopEquipment
7/3/01
Added ShadeControl to Opening
Added ShadeSchedule, SolarOnOpening, HorizontalSolar, AirTempature, ZoneCoolingLoad, and Glare to ShadeControl
Added attributes, enumerations, and documentation for these new elements
Removed frameIdRef, blindIdRef, GlazeId, GapId from Opening - they are redundant and already contained in WindowType
0.30
6/28/01
Changed Results element
Removed MaterialType - it did not add information
0.29
4/30/01
Added StreetAddress element to Building - removed Location.
Changed SIResults element to useSIUnitsForResults.
Made several attributes at the gbXML level required instead of defaulting to SI.
Campus/@buildingType removed - Building/@buildingType required.
Changed SpaceId element to AdjacentSpaceId.
Moved CADObjectId after PlanarGeometry in the Opening element.
Made PlanarGeometry/@id optional.
Removed shadeTypeEnum (no longer used).
4/27/01
Added annotation to several elements and attributes.
Added Enum to the end of enumerations to clarify distinction between 'type', meaning simple type (used for enumerations) and 'type', used in classifying an object (example: buildingType, surfaceType).
0.28
4/12/01
Added uValueUnit.
Made exposedToSun default = true.
4/10/01
Changed sequence of gbXML, Campus, Building, Surface, and Location children.
Added more of a description for Location.
Made Building/@id, Surface/@id optional.
Moved Surface to be child of Campus.
Added enumerations to conditionType.
Changed ShadingSurface element to ExposedToSun boolean attribute.
Renamed SpaceRef to SpaceId, @spaceRef to @spaceIdRef
Removed Name and Description from PlanarGeometry.
Added explicit right-hand-rule documentation to the PolyLoop element.
Constrained PolyLoop to at least 3 CartesianPoints.
Constrained CartesianPoint to exactly 3 Coordinates.
Added @lengthUnit, @areaUnit, @volumeUnit, and @temperatureUnit to the gbXML element.
Changed documentation for Latitude and Longitude.
4/6/01
Added targetNamespace.
Removed gbXML/@version.
Made gbXML/@id optional.
Removed GeoPraxisEAM from gbXML/@engine.
Renamed gbXML/SI to gbXML/SIResults and added documentation.
Removed @unit from Latitude and Longitude and made simple type - must be in decimal degrees.
Added global enumerations to be called out elsewhere.
0.27
2/13/01
Removed buildingType attribute from Space.
Added spaceType attribute to Space.
Changed FloorArea to Area.
Changed CADObjectIdRef attribute to CADObjectId element to allow for multiples.
Changed to surface-centric model.
Changed Geometry to PlanarGeometry, ShellGeometry, and GeneralGeometry
2/12/01
Changing from X3D elements to ifcXML elements.
Removed X3D element.
Placed in alphabetical order.
Seperated complex types from simple type elements.
Changed back to sequence type - all had unusable restrictions.
0.26
2/7/01
Replaced sequence types with type all.
Removed empty sequence elements.
ACCA has given permission to gbxml authors to use this trademark ACCA and Manual J in the gbXML schema. Users of the gbXML schema are restricted from using the ACCA trademarks for any other purposes without express permission from ACCA.
"ASHRAE" is a registered service mark of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. All rights reserved.
Enumerations
Use to specify the most predominant building use type.
Enumeration value to be used when there is no building type information available.
Coefficient of Performance
Energy Efficiency Ratio
Seasonal Energy Efficiency Ratio
Annual Fuel Utilization Efficiency
Heating Seasonal Performance Factor
Thermal Efficiency
Motor Efficiency
Fan Efficiency
Mechanical Efficiency
Boiler Efficiency
Used with the floorCategory attribute.
Used with the floorSlabPerimeterHeatLossCoefficientUnitType attribute.
Used with the hOutsideUnitType attribute.
Opening in a surface with a tilt between 45° and 149.99° with a non-operable glazed opening in it.
Opening in a surface with a tilt between 45° and 149.99° with a operable glazed opening in it.
Opening in a surface with a tilt between 0° and 44.99° with a non-operable glazed opening in it.
Opening in a surface with a tilt between 0° and 44.99° with a operable glazed opening in it.
Opening in a surface with a tilt between 45° and 149.99° with a sliding door in it.
Opening in a surface with a tilt between 45° and 149.99° with a non-sliding door in it.
Opening in a surface with a tilt between 0° and 180° with nothing in it.
Used with the roofASHRAENumber attribute. Each annotation for the values is only one example of many possible constructions for that ASHRAE roof number. The user should select the one that best matches the thermal characteristics of the roof, not necessarily the one closest to the example description.
Undefined
Steel sheet with 1 or 2 inches insulation
One inch wood with 1 inch insulation
Four inch light weight concrete
Two inch heavy weight concrete
One inch wood with 2 inch insulation
Six inch light weight concrete
2.5 inch wood with 1 inch insulation
Eight inch light weight concrete
4 inch hvy wt concrete with 1-2 inch insulation
2.5 inch wood with 2 inches of insulation
Roof Terrace System
6 inch hvy wt concrete with 1-2 inch insulation
4 inch wood with 1-2 inches of insulation
Used with the roofCLTDIndex attribute.
Under attic or knee wall, U-value = 0.408 - 0.018, Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color
Under attic or knee wall, U-value = 0.408 - 0.018, Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane
Under attic or knee wall, U-value = 0.408 - 0.018, Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake Light Metal, Tar and Gravel or Membrane
Under attic or knee wall, U-value = 0.408 - 0.02, Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete
Under attic or knee wall, U-value = 0.408 - 0.02, Vented Attic, No Radiant Barrier, Light Tile, Slate or Concrete
Under attic or knee wall, U-value = 0.408 - 0.02, Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane
On exposed beams, U-value = 0.287 - 0.134, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.118 - 0.091, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.074 - 0.063, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.054, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.048, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.043 - 0.039, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.035, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.032 - 0.027, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
On exposed beams, U-value = 0.287 - 0.134, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.118 - 0.091, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.074 - 0.063, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.054, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.048, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.043 - 0.039, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.035, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.032 - 0.027, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
On exposed beams, U-value = 0.287 - 0.134, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.118 - 0.091, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.074 - 0.063, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.054, White or Light Color Tile Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.048, White or Light Color Tile Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.043 - 0.039, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.035, White or Light Color Tile Slate or Concrete, White Metal, White Membrane
On exposed beams, U-value = 0.032 - 0.027, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Below roof joists, U-value = 0.241 - 0.109, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.09 - 0.076, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.069, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.051 - 0.047, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.034, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.029, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel
Below roof joists, U-value = 0.241 - 0.109, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.09 - 0.076, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.069, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.051 - 0.047, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.034, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.029, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel
Below roof joists, U-value = 0.241 - 0.109, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Below roof joists, U-value = 0.09 - 0.076, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Below roof joists, U-value = 0.069, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Below roof joists, U-value = 0.051 - 0.034, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Below roof joists, U-value = 0.029, White or Light Color Tile, Slate or Concrete, White Metal, White Membrane
Used with the roofColor attribute. Only enter Light if the construction is a roof and if it's in a rural location.
Dark colored or light colored in an industrial area
Permanently light colored and in a rural area
Used with the roofCTSType attribute. Each annotation for the values is only one example of many possible constructions for that CTS type. The user should select the one that best matches the thermal characteristics of the roof, not necessarily the one closest to the example description.
Metal Roof, R-19 Batt Insulation, Gyp Board
Metal Roof, R-19 Batt Insulation, Suspended Acoustical Ceiling
Metal Roof, R-19 Batt Insulation
Asphalt Shingles, Wood Sheathing, R-19 Batt Insulation, Gyp Board
Slate or Tile, Wood Sheathing, R-19 Batt Insulation, Gyp Board
Wood Shingles, Wood Sheathing, R-19 Batt Insulation, Gyp Board
Membrane, Sheathing, R-10 Insulation Board, Wood Deck
Membrane, Sheathing, R-10 Insulation Board, Wood Deck Suspended Acoustical Ceiling
Membrane, Sheathing, R-10 Insulation Board, Metal Deck
Membrane, Sheathing, R-10 Insulation Board, Metal Deck Suspended Acoustical Ceiling
Membrane, Sheathing, R-15 Insulation Board, Metal Deck
Membrane, Sheathing, R-10 plus R-15 Insulation Boards, Metal Deck
2" Concrete Roof Ballast, Membrane, Sheathing, R-15 Insulation Board, Metal Deck
Membrane, Sheathing, R-15 Insulation Board, 4" LW Concrete
Membrane, Sheathing, R-15 Insulation Board, 6" LW Concrete
Membrane, Sheathing, R-15 Insulation Board, 8" LW Concrete
Membrane, Sheathing, R-15 Insulation Board, 6" HW Concrete
Membrane, Sheathing, R-15 Insulation Board, 8" HW Concrete
Membrane, 6" HW Concrete, R-19 Batt Insulation, Suspended Acoustical Ceiling
Department of Energy
Air-Conditioning and Refrigeration Institute
American National Standards Institute
National Electrical Manufacturers Association
A five-digit station identifier assigned by the World Meteorological Organization (WMO), used for international weather data exchange and station documentation.
Weather-Bureau-Army-Navy station id. A five-digit station identifier used at National Climatic Data Center (NCDC) for digital data storage and general station identification purposes.
A 4-letter indicator for geographical locations throughout the world, managed by the International Civil Aviation Organization (ICAO).
A 3- to 5-character alpha-numeric identifier assigned by the US National Weather Service (NWS), used for site identification in the NWS communications systems (e.g. AFOS, ROSA, SHEF, etc.).
An alpha-numeric identifier of up to 4-characters managed by the USDT Federal Aviation Administration (FAA), used for site identification of airports, weather stations and other sites vital to navigation.
A 6-digit number identifying a station in the NWS Cooperative Network.
Surface adjacent to two conditioned or unconditioned spaces with a tilt between 45° and 149.99°.
Surface adjacent to one conditioned or unconditioned space and the outside with a tilt between 45° and 149.99°.
Surface adjacent to one conditioned or unconditioned space and the outside with a tilt between 0° and 44.99°.
Surface adjacent to two conditioned or unconditioned spaces with a tilt between 150° and 180°.
Surface not adjacent to any spaces with tilt between 0° and 180°.
Surface adjacent to one conditioned or unconditioned space and earth (soil) with a tilt between 45° and 149.99°.
Surface adjacent to one conditioned or unconditioned space and earth (soil) below grade with a tilt between 150° and 180°.
Surface adjacent to two conditioned or unconditioned spaces with a tilt between 0° and 44.99°.
Air membrane between two conditioned or unconditioned spaces with a tilt between 0° and 180°.
Surface adjacent to one conditioned or unconditioned space and earth (soil) with a tilt between 0° and 44.99°.
Surface adjacent to one conditioned or unconditioned space and the outside with a tilt between 150° and 180°.
Surface adjacent to one conditioned or unconditioned space and earth (soil) at grade with a tilt between 150° and 180°.
Freestanding column in space specified by its top surface having the same ifcGUID.
Embedded column in wall specified by a surface which is coplanar with (one of) the embedding wall(s).
Variable Temperature
Packaged Single-zone
Ceiling Induction
Constant-volume Reheat Fan
Variable-volume Fan
Powered Induction Unit
Packaged Variable Air Volume
Packaged Variable-Volume Variable-Temperature
Ceiling Bypass
Evaporative Cooling
Multizone Fan
Packaged Multizone
Dual-duct Fan
Fan Coil
Induction Unit
Packaged Terminal Air Conditioner
Water Loop Heat Pump
Residential with cycling furnace and cycling air-conditioner
Residential Variable-Volume Variable-Temperature
Floor Panel Heating
Heating and Ventilating
Unit Heater
Unit Ventilator
Used with the wallASHRAEGroup attribute. Each annotation for the values is only one example of many possible constructions for that ASHRAE wall group. The user should select the one that best matches the thermal characteristics of the wall, not necessarily the one closest to the example description.
4-in. face brick, insulation + 8-in. com. brick
4-in. face brick, 2-in. insul., 4-in. com. brick
4-in. face brick, air space + 4-in. face brick
4-in. face brick + 4-in. common brick
4-in. face brick + 4-in. block
4-in. block + air space or insulation
Metal curtain wall + 1 to 3-in. insulation
Used with the wallColor attribute. Only enter Light or Medium if the construction is a wall and if it's in a rural location.
Dark colored or light colored in an industrial area
Permanently medium colored and in a rural area
Permanently light colored and in a rural area
Used with the wallCTSType attribute. Each annotation for the values is only one example of many possible constructions for that CTS type. The user should select the one that best matches the thermal characteristics of the wall, not necessarily the one closest to the example description.
Spandrel Glass, R-10 Insulation Board, Gyp Board
Metal Wall Panel, R-10 Insulation Board, Gyp Board
1" Stone, R-10 Insulation Board, Gyp Board
Metal Wall Panel, Sheathing, R-11 Batt Insulation, Gyp Board
1" Stone, Sheathing, R-11 Batt Insulation, Gyp Board
Wood Siding, Sheathing, R-11 Batt Insulation, 1/2"
Wood
1" Stucco, Sheathing, R-11 Batt Insulation, Gyp Board
EIFS Finish, R-5 Insulation Board, Sheathing, Gyp Board
EIFS Finish, R-5 Insulation Board, Sheathing, R-11 Batt Insulation, Gyp Board
EIFS Finish, R-5 Insulation Board, Sheathing, 8" LW CMU, Gyp Board
Brick, R-5 Insulation Board, Sheathing, Gyp Board
Brick, Sheathing, R-11 Batt Insulation, Gyp Board
Brick, R-5 Insulation Board, Sheathing, R-11 Batt Insulation Gyp Board
Brick, R-5 Insulation Board, 8" LW CMU
Brick, 8" LW CMU, R-11 Batt Insulation, Gyp Board
Brick, R-5 Insulation Board, 8" HW CMU, Gyp Board
Brick, R-5 Insulation Board, Brick
Brick, R-5 Insulation Board, 8" LW Concrete, Gyp Board
Brick, R-5 Insulation Board, 12" HW Concrete, Gyp Board
Brick, 8" HW Concrete, R-11 Batt Insulation, Gyp Board
8" LW CMU, R-11 Batt Insulation, Gyp Board
8" LW CMU w Fill Insulation, R-11 Batt Insulation, Gyp Board
1" Stucco, 8" HW CMU, R-11 Batt Insulation, Gyp Board
8" LW CMU w Fill Insulation
8" LW CMU w Fill Insulation, Gyp Board
12" LW CMU w Fill Insulation, Gyp Board
4" LW Concrete. R-5 Board Insulation, Gyp Board
4" LW Concrete. R-11 Batt Insulation, Gyp Board
4" LW Concrete. R-10 Board Insulation, 4" LW Concrete
EIFS Finish, R-5 Insulation Board, 8" LW Concrete, Gyp Board
8" LW Concrete. R-11 Batt Insulation, Gyp Board
EIFS Finish, R-10 Insulation Board, 8" HW Concrete, Gyp Board
8" HW Concrete. R-11 Batt Insulation, Gyp Board
12" HW Concrete. R-19 Batt Insulation, Gyp Board
12" HW Concrete
Used with the wallGroupManualJ attribute.
Fastest heat transfer
Medium heat transfer
Slowest heat transfer
Analysis engine used
This attribute specifies the default temperature unit for the entire gbXML document, wherever the temperatureUnit simple type is used.
This attribute specifies the default length unit for the entire gbXML document, wherever the lengthUnit simple type is used.
This attribute specifies the default area unit for the entire gbXML document, wherever the areaUnit simple type is used.
This attribute specifies the default volume unit for the entire gbXML document, wherever the volumeUnit simple type is used.
Results will be given in SI or IP units. True = SI units which is the implied default. If False, results will be in english units.
Absorptance of the outside surface
ID for a space that is bounded by this surface.
With interior horizontal surfaces, this attribute can distinguish between ceiling and floor surfaces to avoid double-counting of floor areas, etc. May be required in future schema versions.
The AirLoop element represents the equipment serving one path of air
A piece of equipment serving an air-loop. This is generalized to be able to contain any type of air loop equipment.
ID pointing at an air loop equipment object
ID pointing to an air loop
Minimum air temperature before shades are closed.
Reflectance of solar radiation
Alternative energy source
Specifies the area of the space or building. This value should be equal to the area enclosed by the physical boundaries of the space, as defined by the intersection of the horizontal plane at the highest floor height and the volumetric model's vertical interior surface planes. Building area should be the sum of space areas whose PeopleNumber element values are greater than zero.
Polygon azimuth. The direction of the outward normal for the polygon (surface or opening) defined in RectangularGeometry element. Azimuth is measured in degrees clockwise from North, where North = 0 degrees. Examples: East = 90 deg, South = 180 deg, West = 270 deg. If CADModelAzimuth is defined, the Azimuth value is relative to the CADModelAzimuth value rather then North.
Type of ballast used
Month and day year schedule begins
Biomass of vegetation
Leakage value obtained from blower door test.
Use this element to define the shell of the building.
Global Unique ID from Industry Foundation Class (IFC) file.
Captures Building Storey Structure
Global Unique ID from Industry Foundation Class (IFC) file.
ID used by a CAD program to reference its internal materials library
The number of degrees (0 to 360) of the angle of positive Y axis from north. (Value of the of Azimuth of Model's North relative to Cardinal North)
The CADObjectId Element is used to map unique CAD object identifiers to gbXML elements. Allows CAD tools to read results from a gbXML file and map them to their CAD objects.
ID reference to unique CAD program defined in DocumentHistory/ProgramInfo element.
The Campus element should be used as the base for all physical objects. On a campus, place one or more buildings.
ID for the weather data used for a heating design day
ID for the weather data used for a cooling design day
Global Unique ID from Industry Foundation Class (IFC) file.
This is the x, y, and z distances from the origin. This element must have three Coordinate elements when representing 3-d space, which represent x, y and z in order. This element must have two Coordinate elements when representing 2-d space.
IfcCartesianPoint
Cooling degree days. CDD is calculated as the number of degrees a mean daily temperature is above a value (specified as the Temperature element), for each day. For example, if the mean temperature in a region rises to 77 degrees for three days during a year, the rest of the time staying below 75, and the Temperature element is set at 75, then CDD = 6.
Cooling degree day value
This is an element from ifcXML that describes a collection of faces that make up a closed shell.
IfcClosedShell
Parameters required by CLTD load calculation method, as described in the 1989 ASHRAE Handbook, Fundamentals volume, pages 26.32 and following. Ignore this element and all elements under it if you are not planning to use that method.
Specifies the number 1 to 13 to use for a roof. See Table 29 page 26.34, 1989 ASHRAE Handbook, Fundamentals volume.
Specifies the wall group code A to G to use for a wall. See Table 31, page 26.36, 1989 ASHRAE Handbook, Fundamentals volume.
Specifies the effective roof color, which depends on the actual color and whether the location is industrial or rural. See page 26.34, 1989 ASHRAE Handbook, Fundamentals volume.
Specifies whether or not a roof has a suspended ceiling under it. See table 29, page 26.34, 1989 ASHRAE Handbook, Fundamentals volume.
Specifies the effective wall color, which depends on the actual color and whether the location is industrial or rural. See page 26.36, 1989 ASHRAE Handbook, Fundamentals volume.
The coefficient of utilization is the ratio of luminous flux on a work plane to the luminous flux emitted by the lamps alone.
Room cavity ratio is a measure of the room cavity proportions.
Conductivity as a function of temperature
A Construction is a combination of layers, such as a wall or a roof
Reference to layers that comprise this construction. Multiple LayerId's order is important and specifies the layering of the layer's referenced materials. The first Surface/AdjacentSpaceId entered will determine how the referenced construction layers are ordered with the first construction layer being in contact with the outside or 2nd Surface/AdjacentSpaceId listed and the last layer in contact with the first Surface/AdjacentSpaceId listed.
Use this attribute to reference objects in the DOE2 library
The Control element should be used for describing how this equipment is controlled.
This is the an x, y, or z length measurement from the origin.
IfcLengthMeasure
Denotes the time this file has been created, as well as the person and program used to create this file.